Product Highlights

  • High Breaking Capacity: 6000A breaking capacity ensures reliable protection against short circuits.
  • Stable Plastic Mechanism: Plastic structure operating mechanism offers better stability and reliability than metal.
  • Multi-Pole Options: Available in 2-pole and 4-pole configurations for versatile circuit protection.
  • Wide Current Range: Rated current options from 16A to 63A to suit various electrical loads.
  • Safety Design: Screw holes sealed with plastic covers to prevent accidental opening and enhance safety.
  • Transparent Signboard: Large transparent signboard allows users to make special marks for identification.
  • DIN Rail Mounting: Designed for easy 35mm DIN rail installation in standard electrical panels.
  • IEC Compliance: Complies with IEC61008-1 and EN61008-2-1 standards for quality assurance.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB

Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB pictures & photos
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB pictures & photos
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB pictures & photos
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB pictures & photos
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB pictures & photos
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB pictures & photos
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
  • Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
  • Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
    Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
  • Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
    Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
  • Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
    Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
  • Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
    Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
  • Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
    Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
  • Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
    Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB

Find Similar Products

Product Description


Product Description

1.CJL1-125 Residual Current Circuit Breaker (RCCB)(without overcurrent protection), suitable for rated voltage 230V at two poles, 400V at four poles, rated current n line 63A, when the person gets an electric shock or the grid leakage current exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply for protecting the safety of human body and electrical equipment can also be used for infrequent switching of circuits and infrequent starting of motors.

2.It complies with standard of IEC61008-1,EN61008-2-1

Product Advantages
1.Operating mechanism is plastic structure, operatingperformance is more stable and reliable than metalstructure. such as release force, mechanical life cycle.For environmental protection is better than metal typeand also the type is new generation mechanism.
2.Inside all current-carrying parts: copper.
3.All screws are with the plastic cover seal the holes,lt's move safety can not open the products in easy.
4.A Big sizes transparent signboard can help user makesome special marks in the signboard area.
5.The very new tripping structure make more safety

Product Parameters

Technical Data

Standards IEC61008-1/IEC61008-2-1
Rated current 16A,20A,25A,32A,40A,50A,63A
Rated voltage 230~1P+N,400V~3P+N
Rated frequency 50/60Hz
Number of pole 2P,4P
Module size 36mm
Circuit type AC type,A type, B type
Breaking capacity 6000A
Rated residual operating current 10,30,100,300mA
Optimum operating temperature -5°C to 40°C
Terminal Tightening torque 2.5~4N/m
Terminal Capacity(top) 25mm²
Terminal Capacity(bottom) 25mm²
Electro-mechanical endurance 4000 cycles
Mounting 35mm DinRail
Suitable Busbar PIN Busbar
 
Detailed Information

Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB



 
certification&company Profile

Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB

More products
 
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB

 

Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB


 

Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB
Cjl1-125 63A 30mA 4p Residual Current Circuit Breakers RCCB



 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2531183". Items marked "verified" are certified.

Watch Video
Watch Video
Zhejiang C&J Electrical Holding Co., Ltd.
Zhejiang C&J Electrical Holding Co., Ltd.
Zhejiang C&J Electrical Holding Co., Ltd.
Zhejiang C&J Electrical Holding Co., Ltd.
Zhejiang C&J Electrical Holding Co., Ltd.
Zhejiang C&J Electrical Holding Co., Ltd.
Zhejiang C&J Electrical Holding Co., Ltd.
Zhejiang C&J Electrical Holding Co., Ltd.

About Our Factory & Business Background

Address
Nxiangyang Industrial Zone, Liushi Town, Yueqing City, Wenzhou, Zhejiang, China

Our Production Capability & Technical Expertise

Main Products
Circuit Breaker, MCB, RCCB RCD, RCBO, MCCB, Solar Inverter, Pure Sine Wave Inverter, Portable Power Station

Our Industry Experience & Global Business Record

Export Year
2021-02-26

FAQ

What is the breaking capacity of this RCCB?
The breaking capacity is 6000A, ensuring effective protection against short circuits.
What are the available pole configurations?
This product is available in 2-pole and 4-pole configurations.
What is the rated current range?
The rated current ranges from 16A to 63A, including 16A, 20A, 25A, 32A, 40A, 50A, and 63A.
Is the operating mechanism made of metal?
No, the operating mechanism uses a plastic structure, which is more stable and reliable than metal.
What standards does this product comply with?
It complies with IEC61008-1 and EN61008-2-1 standards.
How is the product mounted?
It is designed for mounting on a 35mm DIN rail.
Does it offer overcurrent protection?
No, this RCCB is designed without overcurrent protection.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now