Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of US$ 5.67/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Structure characteristics
·Cambered cover and handle make the operation be more comfortable and appearance be more beautiful.
·The indication window of contact position.
·Transparent clamshell with label.
·Protect the circuit under the condition of overload, and the handle is tripped and stopped at the middle position, so as to repair the circuit with fault quickly. The handle cannot be stopped at the position during manual operation.
·lt has earthing fault, electric leakage and isolation and protection function.
·High short circuit current tolerance.
·It has earthing fault, electric leakage and isolation and protection function.
·It is equipped with finger-protection wiring terminal.
·The shell and components are made of high flame resisting, high temperature resisting and impact resisting engineering plastic.
·lf the current of earthing fault or electric leakage exceeds the stipulated value, the circuit will be cut off automatically.
·The dynamic and wire pressure are independent and are not affected by external disturbance and voltage fluctuation.
Technical Data
Standard | IEN61008-1 IEN62423 |
Type | Electronic type (Auxiliary Electromagnetic type) |
Characteristics of residual operation current | and B |
Poles | 1P+N,3P+N |
Rated operating break capability | 10 InA |
Rated current (A) | 25,40,63 |
Rated voltage | AC 240/415 |
Rated frequency | 50/60 HZ |
Rated residual operation current I△n (A) | 0.03, 0.1 and 0.3 |
Rated residual non-operating current I△nno | 0.5I△n |
Rated limited short circuit current | 10 KA |
Rated limited residual short circuit current l△c | 10 kA |
Scope of residual operating current | 0.51△n~I△n |
Wiring height | 19 mm |
Mechanical electrical life | 4,000 cycles |
Wiring section area of terminal | conductor of 25 mm² and below |
Wiring terminal | screw terminal |
Wiring method | column type wiring method |
Tightening torque | 2.0Nm |
Installation | Installation of 35.5mm guide rail / Vertical installation |
Enclosure protection class | IP20 |
Rated current of housing grade Inm(A) |
Poles | Frequency (Hz) |
Rated voltage Ue(V) |
Rated current In(A) |
Rated residual current(A) |
Rated limited short circuit current Inc(A) |
Rated limited residual short circuit current I△C(A) |
63 | 1P+N | 50/60Hz | 240 | 25 40 63 | 0.03 0.1 0.3 | 10000 | 10000 |
3P+N | 415 |
Type | In(A) | I△n(A) | Standard value of breaking time and non-operating time for equality of residual current (I△A ) and following values (S) |
|||
2 I△n | 4 I△n | 10 I△n | 5A,10A,20A,50A,100A,200A | |||
General type | Any value | Any value | 0.3 | 0.15 | 0.04 | 0.04 |
Model | Tripping current I△ /A | ||
AC | 0.5 I△n | ||
A | Angle of retard | I△n>0.01A | I△n<0.01A |
0° | 0.35I△n≤I△≤1.4I△n | 0.35I△n≤I△≤2I△n | |
90° | 0.25I△n≤I△≤1.4I△n | 0.25I△n≤I△≤2I△n | |
135° | 0.1I△n≤I△≤1.4I△n | 0.1I△n≤I△≤2I△n |
Frequency(Hz) | Residual non-operating current | Residual operating current |
150 | 0.5I△n | 2.4I△n |
400 | 0.5I△n | 6I△n |
1000 | I△n | 14I△n |
The component values of different frequencies in the test current (RMS) | The verified correct initial value (RMS) |
||
Rated Frequency | I 1kHz | I FMotor (10Hz) | I △ |
0.138I△n | 0.138I△n | 0.035I△n | 0.2I△n |