Moulded Case Circuit Breaker Cjm1-125L/1300 MCCB
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Breaking Capacity: | Low Voltage Circuit Breakers |
| Operation: | Electric Type |
Diamond Member Since 2021
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
High Repeat Buyers Choice
The supplier has import and export rights
More than 50% of buyers repeatedly choose the supplier
Sign In to see all verified strength labels (24)
Find Similar Products
Basic Info.
- Model NO.
- CJM1-125L/1300
- Speed
- Normal Type Circuit Breaker
- Arc-extinguishing Medium
- Vacuum
- Installation
- Fixed
- Structure
- MCCB
- Poles Number
- 1,2,3,4
- Type
- Circuit Breaker
- Certification
- ISO9001-2000, CE, CCC
- Dielectric Property
- 2500,3000V
- Rated Operatomg Voltage Ue
- 230,400V
- Rated Current of Frame Size Inm
- 63,160,200,250L
- Rated Insulation Voltage Ui
- 400,500,690V
- Standards
- IEC60947-2
- Transport Package
- Normal Package
- Specification
- 63, 100, 160, 225, 400, 630, 800A
- Trademark
- GSM
- Origin
- Wenzhou
- HS Code
- 85362000
- Production Capacity
- 35ka
Product Description
Application
1.CJMM1 series moulded case circuit breaker(hereinafter referred to as circuit breaker) is pplicable for AC 50/60HZ power distribution network
circuit with rated insulation voltage of 800V, rated operation voltage of 690V and rated operation current from 10A to 630A, it's used to distribute power and prevent circuit and power supply equipment from damage due to overload, short circuit, under voltage and other faults, it's also used for infrequent start of motor as well as overload, short circuit and under voltage protection
2.This circuit breaker owns advantages of small volume, high breaking capacity, short arcing (or noarcing)etc, it can be equipped with accessories like alarm contact, shunt release, auxiliary contact etc, it's an ideal product for user.
3.The residual current circuit breaker can either be vertically installed (vertical installation) or be horizontally installed (horizontal installation)
The product is in accordance with the standards of IEC60947-2 and Gb140482
Classification
1.By breaking capacity: a standard type(type S) b higher breaking capacity type(type H)
2.By connection mode: a front board connection, b back board connection, c plugin type
3.By operation mode: a direct handle operation, b rotation handle operation,c electrical operation
4.By number of poles: 1P,2P, 3P, 4P
5.By accessory: alarm contact, auxiliary contact, shunt release, under voltage release.
Normal Service Condition
1.The altitude of the installation site shall not exceed 2000m
2.Ambient air temperature
a.The ambient air temperature shall not exceed +40ºC
b.The average value shall not exceed +35ºC with in 24 hours
c.The ambient air temperature shall not be less than-5ºC
3.Atmosphere condition
a.There lative humidity of atmosp here shall not exceed 50% at highest temperature of +40ºC,and it can be higher atalower temperature,when theaver agelowest temperature in the wettest month doesn't exceed 25ºC can be 90%,conden sationon product surfacedue to temperature change must be takenin to account.
4.The pollution level is class 3
Table1
Note: When the test parameters for the 400V, 6A without heating release
2.Inverse time breaking operation characteristic when each pole of overcurrent release for power distribution is powered on at the same time
3.Inverse time breaking operation characteristic when each pole of overcurrent release for motor protection is powered on at the same time.
4.The instantaneous operation characteristic of circuit breaker for power distribution shall be set as 10in+20%, and the one of circuit breaker formotor protection shall be set as12ln±20%
1.CJMM1 series moulded case circuit breaker(hereinafter referred to as circuit breaker) is pplicable for AC 50/60HZ power distribution network
circuit with rated insulation voltage of 800V, rated operation voltage of 690V and rated operation current from 10A to 630A, it's used to distribute power and prevent circuit and power supply equipment from damage due to overload, short circuit, under voltage and other faults, it's also used for infrequent start of motor as well as overload, short circuit and under voltage protection
2.This circuit breaker owns advantages of small volume, high breaking capacity, short arcing (or noarcing)etc, it can be equipped with accessories like alarm contact, shunt release, auxiliary contact etc, it's an ideal product for user.
3.The residual current circuit breaker can either be vertically installed (vertical installation) or be horizontally installed (horizontal installation)
The product is in accordance with the standards of IEC60947-2 and Gb140482
Classification
1.By breaking capacity: a standard type(type S) b higher breaking capacity type(type H)
2.By connection mode: a front board connection, b back board connection, c plugin type
3.By operation mode: a direct handle operation, b rotation handle operation,c electrical operation
4.By number of poles: 1P,2P, 3P, 4P
5.By accessory: alarm contact, auxiliary contact, shunt release, under voltage release.
Normal Service Condition
1.The altitude of the installation site shall not exceed 2000m
2.Ambient air temperature
a.The ambient air temperature shall not exceed +40ºC
b.The average value shall not exceed +35ºC with in 24 hours
c.The ambient air temperature shall not be less than-5ºC
3.Atmosphere condition
a.There lative humidity of atmosp here shall not exceed 50% at highest temperature of +40ºC,and it can be higher atalower temperature,when theaver agelowest temperature in the wettest month doesn't exceed 25ºC can be 90%,conden sationon product surfacedue to temperature change must be takenin to account.
4.The pollution level is class 3
Table1
| Accessory name | Electronic release | Compound release |
| Auxiliary contact,under voltage release,alam contact | 287 | 378 |
| Two auxiliary contact sets,alarm contact | 268 | 368 |
| Shunt release, alarm contact, auxiliary contact | 238 | 348 |
| Under voltage release,alarm contact | 248 | 338 |
| Auxiliary contact alarm contact | 228 | 328 |
| Shunt release alarm contact | 218 | 318 |
| Auxiliary contact under-voltage release | 270 | 370 |
| Two auxiliary contact sets | 260 | 360 |
| Shunt release under-voltage release | 250 | 350 |
| Shunt release auxiliary contact | 240 | 340 |
| Under-voltage release | 230 | 330 |
| Auxiliary contact | 220 | 320 |
| Shunt release | 210 | 310 |
| Alarm contact | 208 | 308 |
| No accessory | 200 | 300 |
1.Rated value of circuit breakers
| Model | Imax(A) | Specifications(A) | Rated Operation Voltage(V) | Rated Insulation Voltage(V) | Icu(kA) | Ics(kA) | Number of Poles (P) | Arcing Distance(mm) |
| CJMM1-63S | 63 | 6,10,16,20 25,32,40, 50,63 |
400 | 500 | 10* | 5* | 3 | ≤50 |
| CJMM1-63H | 63 | 400 | 500 | 15* | 10* | 3,4 | ||
| CJMM1-100S | 100 | 16,20,25,32 40,50,63, 80,100 |
690 | 800 | 35/15 | 22/5 | 3 | ≤50 |
| CJMM1-100H | 100 | 400 | 800 | 50 | 35 | 2,3,4 | ||
| CJMM1-225S | 225 | 100,125, 160,180, 200,225 |
690 | 800 | 35/15 | 25/5 | 3 | ≤50 |
| CJMM1-225H | 225 | 400 | 800 | 50 | 35 | 2,3,4 | ||
| CJMM1-400S | 400 | 225,250, 315,350, 400 |
690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
| CJMM1-400H | 400 | 400 | 800 | 65 | 35 | 3 | ||
| CJMM1-630S | 630 | 400,500, 630 |
690 | 800 | 50/15 | 35/8 | 3,4 | ≤100 |
| CJMM1-630H | 630 | 400 | 800 | 65 | 45 | 3 |
2.Inverse time breaking operation characteristic when each pole of overcurrent release for power distribution is powered on at the same time
| Item of test Current (I/In) | Test time area | Initial state |
| Non-tripping current 1.05In | 2h(n>63A),1h(n<63A) | Cold state |
| Tripping current 1.3In | 2h(n>63A),1h(n<63A) | Proceed immediately after No.1 test |
3.Inverse time breaking operation characteristic when each pole of overcurrent release for motor protection is powered on at the same time.
| Setting Current Conventional time Initial State | Note | ||
| 1.0In | >2h | Cold State | |
| 1.2In | ≤2h | Proceeded immediately after the No.1 test | |
| 1.5In | ≤4min | Cold State | 10≤In≤225 |
| ≤8min | Cold State | 225≤In≤630 | |
| 7.2In | 4s≤T≤10s | Cold State | 10≤In≤225 |
| 6s≤T≤20s | Cold State | 225≤In≤630 | |
4.The instantaneous operation characteristic of circuit breaker for power distribution shall be set as 10in+20%, and the one of circuit breaker formotor protection shall be set as12ln±20%

Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- circuit breaker
- Moulded Case Circuit Breaker Cjm1-125L/1300 MCCB
Related Categories
Hot Searches
More