Product Features
1.High segmentation capability.
2.RS485 communication, remote switch/close, set parameters.
3.Remote lock and unlock during maintenance.
4.Undervoltage protection: The undervoltage action value can be set, and the undervoltage function can be turned off.
5.Loss of voltage protection: When the undervoltagefunction is opened, it has loss of voltage protection, that ispower trip, and the product cannot be manually closed atthis time.
6.Manual/Automatic setting: Manual or automatic modecan be set.
7.Real-time voltage, curent and power can be read,
8.The circuit breaker should be installed vertically on the mounting rail, and the mounting rail is secured to the rubber board or metal plate with M5 screws.
| Rated operating voltage | AC230V/400V |
| Number of poles | 1P+N/2P/3P/3P+N/4P |
| Frame grade current | 125A. |
| Breaking Capability | lcs 6000A |
| Leakage parameters | Rated residual operating current 10-90mA can be set, and the operating time is less than or equal to 0.1s. |
| Rated current in In | 32A.40A, 50A.63A. |
| Life | Mechanical life 20000 times, electrical life 4000times. |
| Operating characteristics under overpressure |
Setting range of overvoltage action value: AC 240-300V. |
| Overvoltage Recovery Uvor: AC 220-275V | |
| Under-voltage operation characteristics. |
Setting range of undervoltage action value: AC 140-190V. |
| Undervoltage Recovery Value Uvur: AC 170-220V. | |
| Under voltage operation delay: 0.5S-6S. | |
| Power on again after power off |
Set to automatic mode, when no fault is detected, the automatic closing time is less than 3S; if the mode is set to manual, the switch cannot be automatically closed. |
| Wiring | Use clamp wiring terminals. The cross-sectional area of the wire can reach 35 mm. |
| Installation | Install on 35 x 7.5mm standard guide rails. |
| Circuit breaker protection action characteristics |
Circuit breaker in the surrounding air temperature of 30~35 °C (that is, no temperature compensation The operating characteristics of the overcurrent release are shown in Table 1. |
| RS485 communication | Rs485 communication baud rate:9600 |
| Communication | Communication address range:1-247 |