Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of US$ 6/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PUSH BUTTON CONTROL OR TRANSFER SWITCH CONTROL | ||||||||
50/60Hz,AC-3 standard, three-phase motor rated power |
Thermal trip setting range | Magnetic trip current | Ithe current with case | Model(button control) | Weight | |||
230V | 400V | 415V | 440V | |||||
KW | KW | KW | KW | A | A | A | KG | |
- | - | - | - | 0.1~0.16 | 1.5 | 0.16 | GV2-M2001 | 0.26 |
- | - | - | - | 0.16~0.25 | 2.4 | 0.25 | GV2-M2002 | 0.26 |
- | - | - | - | 0.25~0.40 | 5 | 0.40 | GV2-M2003 | 0.26 |
- | - | - | - | 0.40~0.63 | 8 | 0.63 | GV2-M2004 | 0.26 |
- | - | - | 0.37 | 0.63~1 | 13 | 1 | GV2-M2005 | 0.26 |
- | 0.37 | - | 0.55 | 1~1.6 | 22.5 | 1.6 | GV2-M2006 | 0.26 |
0.37 | 0.75 | 0.75 | 1.1 | 1.6~2.5 | 33.5 | 2.5 | GV2-M2007 | 0.26 |
0.75 | 1.5 | 1.5 | 1.5 | 2.5~4 | 51 | 4 | GV2-M2008 | 0.26 |
1.1 | 2.2 | 2.2 | 3 | 4~6.3 | 78 | 6.3 | GV2-M2010 | 0.26 |
2.2 | 4 | 4 | 4 | 6~10 | 138 | 9 | GV2-M2014 | 0.26 |
3 | 5.5 | 5.5 | 7.5 | 9~14 | 170 | 13 | GV2-M2016 | 0.26 |
4 | 7.5 | 9 | 9 | 13~18 | 223 | 17 | GV2-M2020 | 0.26 |
5.5 | 11 | 11 | 11 | 17~23 | 327 | 21 | GV2-M2021 | 0.26 |
5.5 | 11 | 11 | 11 | 20~25 | 327 | 23 | GV2-M2022 | 0.26 |
7.5 | 15 | 15 | 15 | 24~32 | 416 | 24 | GV2-M2032 | 0.26 |
Note: GV2-M20 is the same as GV2-ME14 |
TRANSFER SWITCH CONTROL | ||||||||
50/60Hz,AC-3 standard rated power of three-phase motor | Thermal trip setting range | Magnetic trip current(Id±20%) | Model(button control) | Weight | ||||
230V | 400V | 415V | 440V | |||||
KW | KW | KW | KW | A | A | A | KG | |
- | - | - | - | 0.1~0.16 | 1.5 | GV2-RS3201 | 0.26 | |
- | - | - | - | 0.16~0.25 | 2.4 | GV2-RS3202 | 0.26 | |
- | - | - | - | 0.25-0.40 | 5 | GV2-RS3203 | 0.26 | |
- | - | - | - | 0.40~0.63 | 8 | GV2-RS3204 | 0.26 | |
- | - | - | 0.37 | 0.63~1 | 13 | GV2-RS3205 | 0.26 | |
- | 0.37 | - | 0.55 | 1~1.6 | 22.5 | GV2-RS3206 | 0.26 | |
0.37 | 0.75 | 0.75 | 1.1 | 1.6~2.5 | 33.5 | GV2-RS3207 | 0.26 | |
0.75 | 1.5 | 1.5 | 1.5 | 2.5~4 | 51 | GV2-RS3208 | 0.26 | |
1.1 | 2.2 | 2.2 | 3 | 4~6.3 | 78 | GV2-RS3210 | 0.26 | |
2.2 | 4 | 4 | 4 | 6~10 | 138 | GV2-RS3214 | 0.26 | |
3 | 5.5 | 5.5 | 7.5 | 9~10 | 170 | GV2-RS3216 | 0.26 | |
4 | 7.5 | 9 | 9 | 13~18 | 223 | GV2-RS3220 | 0.26 | |
5.5 | 11 | 11 | 11 | 17~23 | 327 | GV2-RS3221 | 0.26 | |
5.5 | 11 | 11 | 11 | 20~25 | 327 | GV2-RS3222 | 0.26 | |
7.5 | 15 | 15 | 15 | 24~32 | 416 | GV2-RS3232 | 0.26 |
TRANSFER SWITCH CONTROL | ||||||||
50/60Hz,AC-3 standard rated power of three-phase motor | Protection rating | Magnetic trip current(Id±20%) | With JRS4-d overload relay | Model(button control) | Weight | |||
230V | 400V | 415V | 440V | |||||
KW | KW | KW | KW | A | A | KG | ||
- | - | - | - | 0.4 | 5 | JRS4-1303d | GV2-LS3203 | 0.33 |
- | - | - | - | 0.63 | 8 | JRS4-1304d | GV2-LS3204 | 0.33 |
- | - | - | 0.37 | 1 | 13 | JRS4-1305d | GV2-LS3205 | 0.33 |
- | 0.37 | - | 0.55 | 1.6 | 22.5 | JRS4-1306d | GV2-LS3206 | 0.33 |
0.37 | 0.75 | 0.75 | 1.1 | 2.5 | 33.5 | JRS4-1307d | GV2-LS3207 | 0.33 |
0.75 | 1.5 | 1.5 | 1.5 | 4 | 51 | JRS4-1308d | GV2-LS3208 | 0.33 |
1.1 | 2.2 | 2.2 | 3 | 6.3 | 78 | JRS4-1310d | GV2-LS3210 | 0.33 |
2.2 | 4 | 4 | 4 | 10 | 138 | JRS4-1314d | GV2-LS3214 | 0.33 |
3 | 5.5 | 5.5 | 7.5 | 14 | 170 | JRS4-1316d | GV2-LS3216 | 0.33 |
4 | 7.5 | 9 | 9 | 18 | 223 | JRS4-1321d | GV2-LS3220 | 0.33 |
5.5 | 11 | 11 | 11 | 25 | 327 | JRS4-1322d | GV2-LS3222 | 0.33 |
7.5 | 15 | 15 | 15 | 32 | 6 | JRS4-2355d | DZS32-LS3232 | 0.33 |
BUTTON CONTROL | ||||||||
50/60Hz,AC-3 standard rated power of three-phase motor | Thermal trip setting range | Magnetic trip current(Id±20%) | Model(button control) | Weight | ||||
230V | 400V | 415V | 440V | |||||
KW | KW | KW | KW | A | A | KG | ||
- | 0.37 | - | 0.55 | 1~1.6 | 19.2 | GV3-ME50C06 | 0.6 | |
0.37 | 0.75 | 1.1 | 1.1 | 1.6~2.5 | 30 | GV3-ME50C07 | 0.6 | |
0.75 | 1.5 | 1.5 | 1.5 | 2.5~4 | 48 | GV3-ME50C08 | 0.6 | |
1.1 | 2.2 | 2.2 | 3 | 4~6 | 72 | GV3-ME50C10 | 0.6 | |
2.2 | 4 | 4 | 4 | 6~10 | 120 | GV3-ME50C14 | 0.6 | |
4 | 7.5 | 7.5 | 7.5 | 10~16 | 192 | GV3-ME50C20 | 0.6 | |
5.5 | 11 | 11 | 11 | 16~25 | 300 | GV3-ME50C25 | 0.6 | |
1 | 18.5 | 22 | 22 | 25~40 | 480 | GV3-ME50C40 | 0.7 | |
15 | 30 | 33 | 33 | 40~63 | 756 | GV3-ME50C63 | 0.7 | |
22 | 40 | 45 | 45 | 56~80 | 960 | GV3-ME50C80 | 0.7 | |
Note: GV3-ME50C is the same as GV3-M50C |
CEJIA has over 20 years of experience in this industry and has built a reputation for providing quality products and services at competitive prices. We are proud to be one of the most reliable electrical equipment suppliers in China with more. We attach great importance to product quality control from raw materials procurement to finished product packaging. We provide our customers with solutions that meet their needs on a local level, while also giving them access to the latest technology and services available.
We are able to produce large volumes of electrical parts and equipment at very competitive prices in our state-of-the-art manufacturing facility located in China.
Q1:Are you a trading company or manufacturer?
A.We are professional manufacturer for low-voltage circuit breaker series products,Integrates research and development, manufacturing, processing and trade departments together. also we supply of different electrical and electronic items
Q2:About the industrial plug and socket knowledge?
A.The plug and socket is a kind of Europe type plug and socket. It is widely used in many kinds of industrial and mining enterprises such as stell smelting, petrochemical industry, electric power, electron, railway, construction, airport, mine, stope, water supply and drain processing factory, port, store, hotel and so on, and it is also for mating and maintenance fittings of device power and connectors imported from abroad, so it is a new generation ideal power supply unit.
Q3:How to choose the industrial plug and socket?
A.Firstly, consider about the rated current. It has four kind current: 16Amp, 32Amp, 63Amp, 125Amp.
Second: Consider the cable phase; We have 2phase +E 3phase+E or 3phase + N+E
For example: Your equipments is 10-15A, and need connect 3phase + E, then you can choose the plug 16A 3phase+e
Q4: why will you choice us :
A.more than 20years of professional teams will give you good quality products ,good service ,and reasonable price
Q5: Is the MOQ fixed?
A.The MOQ is flexible and we accept small order as trial order.
....
Dear Customers,
If you have any question , please feel free to contact with me , I will send you our catalog for your reference.