• Residual Current Circuit Breaker with Overcurrent Protection RCBO
  • Residual Current Circuit Breaker with Overcurrent Protection RCBO
  • Residual Current Circuit Breaker with Overcurrent Protection RCBO
  • Residual Current Circuit Breaker with Overcurrent Protection RCBO
  • Residual Current Circuit Breaker with Overcurrent Protection RCBO
  • Residual Current Circuit Breaker with Overcurrent Protection RCBO

Residual Current Circuit Breaker with Overcurrent Protection RCBO

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: MCB
Samples:
US$ 6.35/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Information
  • About Us
  • Our Advantages
  • FAQ
  • More products
Overview

Basic Info.

Model NO.
CJL6-32
Poles Number
1p+N
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection
Certification
CE
Residual Current Characteristics
AC
Rated Voltage
240VAC
Rated Current (a)
6,10,16,20,25,32A
Rated Frequency
50/60Hz
Transport Package
Normal Package
Trademark
GSM
Origin
Wenzhou
HS Code
85362000
Production Capacity
500000PCS/Year

Product Description

Product Description

Residual Current Circuit Breaker with Overcurrent Protection RCBO 
CJL6-32 Residual Current circuit breaker with overload protection (RCBO) ensure electrical safety in homes and similar situations, such as offices and other buildings as well as for industrial applications by protecting electrical installations against leakage Current reach to 30mA and against overloads and short circuits. Once a fault is detected, the RCBO automatically switches off the electrical circuit to prevent risk to the people and prevent damage to wires and to avoid the risk of fire. Warranting reliability and safety for people and assets, RCBO are equipped with AC,A type. The AC type is a common type use for homes, A type with pulse DC protection, normally the rated current is 6,10,16,20,25,32A,leakage current protection is 30mA,100mA,300mA and rated voltage is 230VAC. frequency is 50/60Hz. according to IEC61009-1/EN61009-1 standards.

Construction and Feature
1.Provides protection against earth fault/leakage current, short-circuit, overload, and function of isolation.
3.Contact position indication
3.Provides protection against indirect contact by human body 
4.Provides complementary protection against direct contact by human body.
5.Effectively protects electric equipment against insulating failure
6.Equipped with switched neutral and phase pole
7.Provides protection against over-voltage
8.Provides comprehensive protection to household and commercial distribution systems.
9.S2 Shunt Tripper
10.U2+O2 Over-voltage and under-voltage tripper

Product Parameters
Standard IEC61009-1/EN61009-1
Type Electronic type
Residual current characteristics AC
Pole No 1P+N
Tripping curve B, C, D
Rated short-circuit capacity 4.5kA
Rated current (A) 6A, 10A, 16A, 20A, 25A, 32A
Rated voltage 240V AC
Rated frequency 50/60Hz
Rated residual operating current(mA) 0.03, 0.1, 0.3
Tripping duration instantaneous≤0.1s
Electro-mechanical endurance 4000 cycles
Connection terminal pillar terminal with clamp
Terminal Connection Height H1=16mm  H2=21mm
Over-voltage tripping 280V±5%
Connection capacity Flexible conductor 10mm²
Rigid conductor 16mm²
Installation On symmetrical DIN rail 35.5mm
Panel mounting


Overload Current Protection Characteristics
Test procedure Type Test Current Initial State Tripping or Non-tripping Time Limit Expected Result Remark
a B,C,D 1.13In cold t≤1h no tripping  
b B,C,D 1.45In after test a t<1h tripping Current in the 5s in th increase of stability
c B,C,D 2.55In cold 1s1s tripping  
d B 3In cold t≤0.1s no tripping Turn on the auxiliary switch to
close the current
C 5In
D 10In
e B 5In cold t<0.1s tripping Turn on the auxiliary switch to
close the current
C 10In
D 20In
The terminology  "cold state" refes to that no load is carried before testing at the reference setting temperature.


Residual Current Action Breaking Time
type In/A I△n/A Residual Current (I△) Is Corresponding To The Following Breaking Time (S)
I△n 2 I△n 5 I△n 5A,10A,20A,50A,100A,200A,500A I△t  
general
type
any
value
any
value
0.3 0.15 0.04 0.04 0.04 Max Break-time


A Type Of Trip Current Range
Lagangle(A) A Tripping Current(A)
Lower Limit Upper Limit
0.35 I△n 0.14 I△n
90° 0.25 I△n
135° 0.11 I△n
 
 
Detailed Information

Residual Current Circuit Breaker with Overcurrent Protection RCBO

About Us
Residual Current Circuit Breaker with Overcurrent Protection RCBO

 

Our Advantages

CEJIA has over 20 years of experience in this industry and has built a reputation for providing quality products and services at competitive prices.     We are proud to be one of the most reliable electrical equipment suppliers in China with more.   We attach great importance to product quality control from raw materials procurement to finished product packaging.  We provide our customers with solutions that meet their needs on a local level, while also giving them access to the latest technology and services available.

We are able to produce large volumes of electrical parts and equipment at very competitive prices in our state-of-the-art manufacturing facility located in China.

FAQ

Q1:Are you a trading company or manufacturer?
A.We are professional manufacturer for low-voltage circuit breaker series products,Integrates research and development, manufacturing, processing and trade departments together. also we supply of different electrical and electronic items 

Q2.tell me the standard of package?   
A.Normally are cartons, but also we can pack it according to your requirement.

Q3. Can i take some samples?
A.Yes, we support to take samples before place the order. Just feel free to contact with us if you have any requirements.

Q4. How can you make sure the quality of the products?
A.We will accord to international quality standards to inspect every item before leaving our factory
....

Dear Customers,

If you have any question , please feel free to contact  with me , I will send you our catalog for your reference.



 
More products
Residual Current Circuit Breaker with Overcurrent Protection RCBO
Residual Current Circuit Breaker with Overcurrent Protection RCBO
Residual Current Circuit Breaker with Overcurrent Protection RCBO

 

Residual Current Circuit Breaker with Overcurrent Protection RCBO
Residual Current Circuit Breaker with Overcurrent Protection RCBO
Residual Current Circuit Breaker with Overcurrent Protection RCBO
 
Residual Current Circuit Breaker with Overcurrent Protection RCBO
Residual Current Circuit Breaker with Overcurrent Protection RCBO
Residual Current Circuit Breaker with Overcurrent Protection RCBO

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
>2000 square meters