High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
>2000 square meters
  • High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
  • High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
  • High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
  • High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
  • High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
  • High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
Find Similar Products
  • Overview
  • Product Description
  • Main Technical Parameter
  • About Us
  • More products
Overview

Basic Info.

Model NO.
CJMM6RT-160M/4300
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
MCCB
Poles Number
3,4
Type
Circuit Breaker
Certification
ISO9001-2000, CE, CCC
Rated Voltage Ue
AC400V
Rated Current of Frame Size Inm
125,160,250,400,630,800,1250,2000
Rated Insulation Voltage Ui
1000V
Standards
IEC60947-2
Transport Package
Normal Package
Specification
16A-1600A
Trademark
C&J and OEM
Origin
Wenzhou
HS Code
85362000
Production Capacity
35ka

Product Description

Product Description

CJMM6RT series thermomagnetic double adjustable moulded case circuit breaker

High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
 
Main Technical Parameter

Main performance indicator

Model CJMM6RT/A-125 CJMM6RT-160 CJMM6RT-250
Frame current In 16A,20A,25A,32A,40A,50A,
63A,80A,100A,125A,
25A,32A,40A,50A,63A,
80A,100A,125A,140A,160A
100A,125A,140A, 160A,
180A,200A,225A,250A
Short circuit breaking
capacity code
C S M H C S M H C S M H
Number of poles 3P/4P
Rated working
voltage Ue (V), AC
AC400V
Rated insulation
voltage Ui (V)
1000V
Rated impulse withstand
voltage Uimp (kV)
8kV
Rated service
short-circuit
breaking capacity
Ics (%Icu)
AC
400V
5kA 10kA 18kA 50kA 5kA 10kA 10kA 50kA 5kA 8kA 10kA 50kA
Rated ultimate
short-circuit
breaking capacity
Icu (kA)
10kA 20kA 36kA 50kA 8kA 20kA 20kA 50kA 8kA 15kA 20kA 50kA
Selective category Class A
Overcurrent release type Thermomagnetic type
CJMM6RT outline
dimension(mm)

Width (W)*Length
(L)*Height (H)
Frame current CJMM6RT/A-125 CJMM6RT-160 CJMM6RT-250
Number of poles 3P 4P 3P 4P 3P 4P
Width 75 100 90 120 105 140
Length 130 130 155 155 165 165
Height/face cover 68 68 68 82 68 82 68 88 68 88
Height/handle 94.5 94.5 94 108 94 108 96 116 96 116
 
Model CJMM6RT-400  CJMM6RT-630  CJMM6RT-800  CJMM6RT-1250  CJMM6RT-2000
Frame current In 320A,350A,400A 400A,500A,630A 630A,700A,800A 1000A,1250A 1600A
Short circuit breaking
capacity code
M H M H M H M H M H
Number of poles                    
Rated working
voltage Ue (V), AC
                   
Rated insulation
voltage Ui (V)
                   
Rated impulse withstand
voltage Uimp (kV)
                   
Rated service
short-circuit
breaking capacity
Ics (%Icu)
AC
400V
50kA 50kA 50kA 50kA 50kA 65kA 50kA 65kA 50kA 85kA
Rated ultimate
short-circuit
breaking capacity
Icu (kA)
50kA 50kA 50kA 50kA 65kA 85kA 65kA 85kA 50kA 100kA
Selective category                    
Overcurrent release type                    
CJMM6RT outline
dimension(mm)

Width (W)*Length
(L)*Height (H)
Frame current CJMM6RT-400 CJMM6RT-630 CJMM6RT-800 CJMM6RT-1250 CJMM6RT-2000
Number of poles 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P
Width 140 184 140 184 210 280 210 280 210 280
Length 257 257 257 257 275.5 275.5 275.5 275.5 340 340
Height/face cover 103 103 103 103 103 103 103 103 141 141
Height/handle 152 152 152 152 152 152 152 152 244 244
Note: The height from the bottom of the base to the (face cover/handle)


CJMM6RT external accessories 
NO In(A) Parameters Index requirements
1 160-1250 Overload long-delay tripping setting current (A) 0.7~1.0ln adjustable (optional)
2 0.8~1.0ln adjustable (optional)
3 Short-circuit instantaneous tripping setting current (A) 5ln~10ln adjustable (optional)
4 Short-circuit protection When 0.8*(5ln/10ln), it will not work within 0.2s
5 When 1.2*(5ln/10ln), it will work within 0.2s
6 125 Overload long-delay tripping setting current (A) 0.7~1.0ln adjustable (optional)
7 0.8~1.0ln adjustable (optional)
About Us

 

High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker

 
More products
 
High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker

 

High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker


 

High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker
High Quality Cjmm6rt 3p 4p Safety Thermomagnetic Double Adjustable Moulded Case Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier